Description

System
The experiments are carried out with the small controller LOGO! 8 from Siemens. The logic module is set on a base plate and hung in a profile frame. The students are expected to program the LOGO! 8 and learn the main functions of small controllers in the process.

Objectives

  • Operating a small controller.
  • Creating programs.
  • Learning logistics and control functions.
  • Testing the programs
  • Configuring network connections

Characteristics
The learning system is comprised of:

  • LOGO8! 12/24 RCE
  • EXPANSION MODULE LOGO! DM8 12/24R
  • Base plate small controller

Description of the base plate small controller

  • 14 digital inputs and 10 transistor outputs connected with the base plate via a 4 mm safety connector
  • Inputs can be wired with the notch and push function with the incorporated switches.
  • Connectors can be designed for 24 V.
  • Analogue signals can be processed over two analogue inputs and two analogue outputs.
  • Control device with ethernet interface (RJ 45)
  • Control voltage: 24 V DC

Method
Student experiments are carried out following the tasks set in the experiment description.

Target Group
Students completing vocational training in electrical engineering for a trade or industry are the target group addressed. The course conveys knowledge on an intermediate level.

Previous knowledge

  • Basics of contactor controls
  • Programming small controllers
  • nstruction in the dangers of electrical technology

Add - ons

The learning system can be supplemented with the following equipment:

  • E6.5.2.1 a Contactor controls with modules, 24 V
  • E6.5.2.2 a Contactor control with experimental plates, 24 V
  • E6.5.2.5 Controlling with limit and proximity switches
  • E6.7.1.1 ASIMA for small controllers.

Topics

  • Programming a small controller
  • Logic connections
  • Timer and clock timer functions
  • RS components
  • Measure counting and frequencies
  • Analogue value processing
  • Desired value and controlling
  • Webserver
  • App for LOGO!8

Components of equipment sets

1 773041 LOGO! 8 12/24 EW
1 773010  8  Power Supply DC 24 V / 6.5 A LD
1 562793  4  Plug-in power supply for torsion pendulum LD
1 6893000  4  RJ45 crossover Cable 2m LD
HMI   Basic system with software:
1 773055 * HMI Touch Panel Basic EW
1 773090  4  Logo! Software EW
1 72610  4  * Panel frame T150, two-level LD
1 50059  8  * Safety bridging plugs, black, set of 10 LD
1 500591  4  * Safety bridging plugs, yellow/green, set of 10 LD
1 773050 * ASIMA Plant Simulator II EW
1 70000CBT * DVD: COM3LAB Software LD
1 A selection of 12 masks can be found in E6.7.1.1.
1 77304901  4  Mask M1 Logic basic functions LD
1 77304902  4  Mask M2 Digital function modules LD
1 77304903  4  Mask M3 Motor ON/OFF LD
1 77304904  8  Mask M4 Reversing contactor LD
1 77304905  4  Mask M5 Star-delta connection LD
1 77304906  8  Mask M6 Reversing star-delta connection LD
1 77304907  4  Mask M7 Pendulum table control LD
1 77304908  4  Mask M8 Dahlaner circuit LD
1 77304909  8  Mask M9 Motor with 2 windings LD
1 77304910  4  Mask M10 Motor self-starter LD
1 77304911  8  Mask M11 Conveyor belt system LD
1 77304913  4  Mask M13 Heating control LD
1 8-2600001-000-10-0  4  Transparent folder, 410 mm x 320 mm x 10 mm EW
1 775790DE  4  LIT-print: ASIMA, German LD
1 775790EN  4  LIT-print: ASIMA LD
24 500624  4  * Safety experiment cable, 50 cm, black LD
1 500621  4  * Safety experiment cable, 50 cm, red LD
1 500622  4  * Safety experiment cable, 50 cm, blue LD
1 additionally required: 1 PC with Windows 7 / 8.1 / 10 (x86 or x64)
Experiments require the Siemens software LOGO! to create programs.
The equipment can require additional software modules.

Articles marked with * are not essential, we do however recommend them to carry out the experiment.

Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us