AC transformer, 0.3

VE2.3.1.3
AC transformer, 0.3
AC transformer, 0.3

This product is classified as a dangerous good and is not available for online purchase.

For ordering the dangerous good or other information please contact our customer service center.
This experiment/set up contains dangerous goods.
These are not available for online purchase.
You may order the experiment/set up without the dangerous goods.


For ordering the dangerous good or other information please contact our customer service center.
Email: webshopuk@ld-didactic.de
Telephone:+49 (0) 22 33 / 604 – 319
Go to contact form

˟

Request an offer

Thank you for your inquiry. We will get back to you as soon as possible.

˟

Description

The experiments are carried out using transformers on training panels in panel frames.

Objectives

  • Protective measures and electrical safety
  • Set-up of power generation systems according to circuit diagrams
  • Use of a power analyser as a measuring device
  • Fundamental circuits of the transformers

This individual equipment set is used to investigate AC transformers. The AC transformer (single-phase transformer) is a standard module which can be used for many applications across the whole of electrical engineering. This transformer is suitable for the investigations of the equivalent circuit diagram with short-circuit, open-circuit and load test.

 Highlights:

With the single-phase transformer, especially the equivalent circuit can be calculated with the Power Analyser.The hysteresis of the transformer iron is examined in an experiment and compared with the iron losses from the no-load test.

All functions of the Power Analyser CASSY can be operated quickly and directly via the display, the rotary wheel and the buttons on the unit. All settings and measurement results can be saved on the unit and quickly called up again later or simply downloaded.

In addition, the Power Analyser CASSY is fully controllable in real time via RJ45 Ethernet, W-LAN and USB-C interfaces.

These interfaces can be used by the following software:

  • CASSY Lab 2 for drives and energy systems,
  • MATLAB® and LabVIEW ™
  • Lab Docs Editor Advanced

The following integrated servers are available in the Power Analyser CASSY for the local media connection of at least four end devices simultaneously.

For more details, see product data 727110 or 727111 Power Analyser CASSY.

The individual equipment is equally suitable for student experiments in the laboratory with low voltage (230 / 400 V three-phase current) and - with a mobile trainer - for teacher demonstration in the classroom. The experiments are carried out according to the manual.

The target group is made up of commercial apprentices and students of electrical machine construction. The course offers experiments at an intermediate level and also allows for the necessary insight into machine behaviour for scientific interpretation at undergraduate level. The media connection makes the experiments suitable for demonstration in the classroom or a lecture hall.

In the following configurations there are further extended experiments with transformers:

  • E2.3.1.1 Three-phase transformer
  • E2.3.1.2 Scott transformer
  • E2.3.1.4 AC toroidal core transformer
  • E2.3.1.5 AC auto-transformer

Topics

  • Voltage equation and equivalent circuit
  • Measurement without load, with load and with a short-circuit
  • Determination of self-inductance, magnetic coupling and leakage
  • Losses, changes in voltage and efficiency

Components of equipment sets

1 73397  8  1-phase transformer, 0.3 LD
1 773361 Controllable resistive load, 1.0 LD
1 773363 Controllable capacitive load, 1.0 LD
1 773364 Controllable inductive load LD
Manuals:
1 775220DE  4  LIT-print: Transformers 1.0, German LD
1 775220EN  4  * LIT-print: Transformers 1.0 LD
1 727111 Power Analyser CASSY Plus LD
1 524222 * CASSY Lab 2 for Drives and Power Systems LD
Power supply:
1 72685  8  Adjustable transformer 0...260 V LD
1 72609  4  Panel frame T130, two-level LD
2 50059  8  Safety bridging plugs, black, set of 10 LD
1 500591  4  Safety bridging plugs, yellow/green, set of 10 LD
1 500855  4  Safety experiment cables, 32 A, set of 34 LD
1 500856  4  Safety experiment cables, 32 A, yellow/green, set of 5 LD
Additionally recommended:
PC with Windows 7/8/10

Articles marked with * are not essential, we do however recommend them to carry out the experiment.

Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us