Converter Controller CASSY

LD 7735291
Converter Controller CASSY
Article not yet available!

Description

Multifunctional control unit for drive technology.

Scalar frequency converter

Control unit with microcontroller for the assembly of a frequency converter in accordance with the PWM characteristic curve method in operation together with the universal converter. A three-phase pulse width modulator controls the six power transistors of the universal converter and thus generates a sinusoidally-shaped motor current. The r.m.s. value of the motor voltage is set in accordance with a programmable, dynamically adapting U/f characteristic. Can be parametrised via 14 menu items. Display of current, voltage or frequency desired/actual value as well as all parameters via four-digit LED display. Desired value input either via external analogue interface -10 V...+10 V or internal manual input via rotary encoder.

Block commutation

Control unit with microcontroller for the assembly of a highly-dynamic AC servo drive with block signal-shape commutation in operation together with the permanently excited brushless DC machine (AC servo), the universal converter and the commutation pick-up. Alternatively, a synchronous or a multifunction machine 0.3 kW can be used. The pulse width modulation is selected so that block-shaped currents are generated in the motor windings. The digital controllers for current, speed and positioning are arranged in cascade configuration. The actual speed value is generated internally out of the commutation signals or measured with an incremental tacho-generator. Commutation signals can also be used for positioning with low resolution (30 degrees). Higher resolution servo positioning is possible by connecting an external servo controller via the parallel interface and an external position pick-up.

Sine commutation

Control unit with microcontroller for the assembly of highly-dynamic AC servo drives with sinusoidal signal-shape commutation in operation together with the permanently excited brushless DC machine (AC servo), the universal converter 735297 and the resolver 731094. Alternatively, a synchronous or a multifunction machine 0.3 kW can be used. The pulse width modulation is designed so that sinusoidal shaped currents are generated in the motor windings. The digital controllers for current, speed and positioning are arranged in cascade configuration. The actual speed value is generated internally out of the resolver signals. The resolver permits positioning with high resolution (10 bit/360 degrees, corresponding to 0.35 degrees).

Position Controller

The microprocessor-controlled digital position controller, in conjunction with the AC servo drive with block commutation, is used to set up a high-precision single-axis positioning drive. Actual positions can be recorded with the incremental tacho 0.3 (773 1092), which supplies 1024 pulses per rotation.

Measuring system:

The measuring system corresponds to that of the 727100 Power Analyser CASSY, a combination of a potential-free and differential oscilloscope, multimeter, wattmeter, energy analyser and recorder. Its concept has been designed for demonstration and laboratory testing.

The measuring system has been optimised for the application area of drive technology:

MEASURING SYSTEM - IN DETAIL

  • Simultaneous measurement of U, I, φu, φ, f and P in 4 channels
    • Instantaneous values U, I and P
    • Averaged values U, I and P
    • RMS values (AC+DC) U and I
    • RMS values (AC) U and I
    • Fundamental wave filters
    • Delta connection adjustment
  • Universal connection options
    • Via USB-C connection with PC or laptop
    • Via WiFi with the school network or setting up an access point
  • Automatic or manual measuring range selection
  • Support of the measurement software CASSY Lab 2 for drives and power systems 524 222, for computer-aided measurements and simple to highly complex evaluations.
  • Formula
    • Electrical power calculation S, P, QC and QL
    • Electrical work WS, W and WQ
    • Resistance calculation R, Z, XC, XL, G, Y BC and BL
    • Positive sequence component, negative sequence component and zero sequence component in 3-phase systems
    • Derivative with respect to time, integral over time, FFT analysis, mean value, histogram, and model
    • Drivers allow you to evaluate the data with LabVIEW and MATLAB
  • Possibility of manual operation directly on the device by means of a rotary selector with cursor keys
  • Direct reading in 9 cm, backlit display
    • Display of up to 24 measured values in one display
    • Display of all values for each channel
    • Display of all values in tabular form
    • Display of measured values in diagram
    • Display of a vector diagram
  • Wireless connection to the CASSY app via WiFi for experimenting with tablet and smartphone (iOS, Android and Windows)
  • Measuring instrument category CAT III 300: allows the use of the measuring instrument from tests with safety extra-low voltage (SELV) via 3-phase systems with or without neutral conductor up to testing in power electronics, e.g. link voltage of 700 V DC
  • FPGA-based real-time processing in the device enables comprehensive network analysis in the three-phase networks, which are displayed directly on the device in the vector diagram

Technical data

The measuring system has been optimised for the application area of drive technology:

MEASURING SYSTEM - IN DETAIL

  • Simultaneous measurement of U, I, φu, φ, f and P in 4 channels
    • Instantaneous values U, I and P
    • Averaged values U, I and P
    • RMS values (AC+DC) U and I
    • RMS values (AC) U and I
    • Fundamental wave filters
    • Delta connection adjustment
  • Universal connection options
    • Via USB-C connection with PC or laptop
    • Via WiFi with the school network or setting up an access point
  • Automatic or manual measuring range selection
  • Support of the measurement software CASSY Lab 2 for drives and power systems 524 222, for computer-aided measurements and simple to highly complex evaluations.
  • Formula
    • Electrical power calculation S, P, QC and QL
    • Electrical work WS, W and WQ
    • Resistance calculation R, Z, XC, XL, G, Y BC and BL
    • Positive sequence component, negative sequence component and zero sequence component in 3-phase systems
    • Derivative with respect to time, integral over time, FFT analysis, mean value, histogram, and model
    • Drivers allow you to evaluate the data with LabVIEW and MATLAB
  • Possibility of manual operation directly on the device by means of a rotary selector with cursor keys
  • Direct reading in 9 cm, backlit display
    • Display of up to 24 measured values in one display
    • Display of all values for each channel
    • Display of all values in tabular form
    • Display of measured values in diagram
    • Display of a vector diagram
  • Wireless connection to the CASSY app via WiFi for experimenting with tablet and smartphone (iOS, Android and Windows)
  • Measuring instrument category CAT III 300: allows the use of the measuring instrument from tests with safety extra-low voltage (SELV) via 3-phase systems with or without neutral conductor up to testing in power electronics, e.g. link voltage of 700 V DC
  • FPGA-based real-time processing in the device enables comprehensive network analysis in the three-phase networks which are displayed directly on the device in the vector diagram

DISPLAY& OPERATION

  • Graphic display: 9 cm (3.5"), QVGA, coloured, light (adjustable up to 400 cd/m²)
  • Operation: pushbutton and incremental encoder with pushbutton

INPUTS & OUTPUTS

  • Inputs: 4 isolated measuring channels CAT III 300, each with I and U
  • Measurement (max. 8 can be used at the same time)
  • Input A-D: U and I connection via 4 mm safety sockets
  • Measuring ranges U: 25/70/250/700 V AC ±36/±100/±360/±1000 V DC
  • Measuring ranges I: 0.7/1.6/7/16 A AC ±1/ 2.5/±10/±16 A DC
  • Sampling rate: max. 1,000,000 values/s per channel for U, max. 500,000 values/s for I

GENERAL

  • Speaker: error message when exceeding the measuring ranges
  • Data storage: 100,000 readings for each measurement series, integrated micro SD card (4 GB) for over a thousand measurement files and screenshots
  • WiFi: 802.11 b/g/n as access point or client (WPA/WPA2)
    VNC server: integrated
  • LAN connection via Ethernet (RJ-45 socket)
  • USB ports: type C connection
  • Mains voltage: 230 V 50–60 Hz (conversion to 115 V possible)
  • Power rating: 50 W
  • Dimensions: 300 mm x 300 mm x 180 mm
  • Weight: 3.7 kg

Scope of delivery

  • 1 Power cord
  • 1 USB C / As cord

Downloads

Web Link Web Link CASSY.App Web
ZIP ZIP Mobile Config, Mobile Edit and Converter Controller CASSY Firmware (V1.10)
Utilities and firmware update without CASSY Lab 2
MSI MSI CASSY Lab 2 for Drives and Power Systems (en, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (fr, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (es, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (pt, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (it, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (nl, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (ru, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
MSI MSI CASSY Lab 2 for Drives and Power Systems (zh, V2.29)
Free demo version, full version requires a licence code of CASSY Lab 2 for Drives and Power Systems
Manual Manual CASSY Lab 2 Manual (en)
Manual Manual CASSY Lab 2 Manual (fr)
Manual Manual CASSY Lab 2 Manual (es)
Web Link Web Link CASSY Lab 2 Web Help (en)
Web Link Web Link CASSY Lab 2 Web Help (fr)
Web Link Web Link CASSY Lab 2 Web Help (es)
ZIP ZIP CASSY SDK for own software development (Windows/Linux)
ZIP ZIP LabVIEW driver for LabVIEW 2017 or higher (Windows)
ZIP ZIP MATLAB driver with examples (Windows)
Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM

Repair Service
You would like to register a repair? FORM

Europe
For European distributors, please visit: European distributors
Worldwide requests
Please contact us per email: sales@ld-didactic.de

 Click here for our contact form and postal address.

Contact Us