Investigating the Kerr effect in nitrobenzene

VP5.4.4.1
Investigating the Kerr effect in nitrobenzene
Investigating the Kerr effect in nitrobenzene

This product is classified as a dangerous good and is not available for online purchase.

For ordering the dangerous good or other information please contact our customer service center.
This experiment/set up contains dangerous goods.
These are not available for online purchase.
You may order the experiment/set up without the dangerous goods.


For ordering the dangerous good or other information please contact our customer service center.
Email: webshopuk@ld-didactic.de
Telephone:+49 (0) 22 33 / 604 – 319
Go to contact form

˟

Request an offer

Thank you for your inquiry. We will get back to you as soon as possible.

˟
This product contains dangerous substances!

Description

The experiment P5.4.4.1 demonstrates the Kerr effect for nitrobenzol, as the Kerr constant is particularly great for this material. The liquid is filled into a small glass vessel in which a suitable plate capacitor is mounted. The arrangement is placed between two polarization filters arranged at right angles, and illuminated with a linearly polarized light beam. The field of view is dark when no electric field is applied. When an electric field is applied, the field of view brightens, as the light beam gets elliptically polarized when passing through the birefringent liquid.

Components of equipment sets

1 47331 Kerr cell LD
1 450641  8  Halogen lamp 12 V, 50/100W LD
1 45063  4  Halogen bulb 12 V/100 W, G6.35 LD
1 45066  8  Picture slider LD
1 46881 Interference filter 620 nm, 50 x 50 mm² LD
1 46805  4  Light filter, yellow LD
1 46883 Interference filter 546 nm, 50 x 50 mm² LD
1 46811  4  Light filter, blue with violet LD
2 472401  4  Polarisation filter LD
1 46003  4  Lens in frame, f=100 mm LD
1 46025  8  Prism table LD
1 44153  8  Screen, translucent LD
1 46032  8  Optical bench with standardised profile, 1 m LD
6 460373 Optics rider, 60/50 LD
1 726890  8  DC power supply unit 1...32 V/0...20 A LD
1 52170  8  High-voltage power supply, 10 kV LD
2 501051  4  Cable for high voltages, 1.5 m LD
1 50098  8  Safety adapter sockets, black, set of 6 LD
2 500624  4  Safety experiment cable, 50 cm, black LD
1 6739410  4  Nitrobenzene, 250 ml LD
GHS06GHS08GHS09 Danger H351 H361f H301 H311 H331 H372 H411

Experiment Instructions

PDF (Experiment description) PDF (Experiment description) P5.4.4.1 Investigating the Kerr effect in nitrobenzene
Print page

Contact Us

Technical Service & Support:

Online Service Portal
Do you have any questions or suggestions regarding our devices, products, experiments, equipment sets or about our software? You need spare parts? FORM